Home


Shop


Tests


Testimonials


Videos


Questions


Distributors


Contact


Links

 

Dear Sir,

The following are the test results on a spray lube oil sample sent for the following tests.

Sample I.D.; SAPL

Tests

Results

1. Falex E.P. properties ASTM D-3233

 

         Procedure A True Load Failure, lb-f

3150

         Procedure B True Load Failure, lb-f

3000

2.  Falex wear properties:  ASTM D-2670

 

         at 865 ft-lb, number of teeth wear

None

3.  Extreme pressure properties, ASTM  D-2783

 

         Load Wear Index

88.92

        Weld Point, Kg

500

4.  Wear preventive properties, ASTM  D-2266

 

         Average Scar Diameter mm

0.87

5.  Timken, OK load, ASTM D-2782 lbs.

60

6.  Viscosity at 210 ºF cSt, ASTM D-445

50.7

         SUS

235.77

7.  Viscosity at 210 ºF cSt, ASTM D-445

7.0

         SUS

49.01

8.  Viscosity index calculation D-2270

104.0

9.  Pour Point, ºC ASTM D-47

-21

10. Flash Point, ASTM D-56, ºF

275

11. Flash Point, ASTM D-92, ºF

315

12. Flash Point, ASTM D-93, ºF

270

13. Coefficient of Friction, ASTM D-2266, modified

0.0223

14. Salt spray test, 100 hours at 5 % Salt Solution

No Rust

If you have any questions regarding these results call (512) 522 3006.

Sincerely,
Geronimo A. Estrada
Manager - Special Projects
Petroleum Products Research Dept.
Automotive Products & Emissions Res.