Dear Mr. Sir,

   The following are the test results on an oil sample sent for the following tests.

 

Sample I.D. ; SAPL

 

TESTS

RESULTS

1. Falex E.P. Properties ASTM D-3233

 

         Procedure A True Load Failure, lb-f

3150

         Procedure B True Load Failure, lb-f

3000

2.  Falex Wear Properties:  ASTM D-2670

 

         at 865 ft-lb, number of teeth wear

NONE

3.  Extreme Pressure Properties, ASTM  D-2783

 

         Load Wear Index

88.92

        Weld Point, Kg

500

4.  Wear Preventive Properties, ASTM  D-2266

 

         Average Scar Diameter mm

0.87

5.  Timken, OK Load, ASTM D-2782 lbs.

60

6.  Viscosity at 210oF cSt, ASTM D-445

50.7

         SUS

235.77

7.  Viscosity at 210oF cSt, ASTM D-445

7.0

         SUS

49.01

8.  Viscosity Index Calculation D-2270

104.0

9.  Pour Point, oC ASTM D-47

-21

10. Flash Point, ASTM D-56, oF

275

11. Flash Point, ASTM D-92, oF

315

12. Flash Point, ASTM D-93, oF

270

13. Coefficient of Friction, ASTM D-2266, modified

0.0223

14. Salt Spray Test, 100 hours at 5% Salt Solution

No Rust


If you have any questions regarding these results call (512) 522 3006.

Sincerely,
Geronimo A. Estrada
manager - Special Projects
Petroleum Products Research Dept.